| Inspection |
| 1. |
Turn the ignition switch OFF and disconnect the battery negative (-) cable. |
| 2. |
Disconnect the fuel pressure regulator valve connector. |
| 3. |
Measure resistance between the fuel pressure regulator valve terminals 1 and 2. |
| 4. |
Check that the resistance is within the specification.
|
Canister Close Valve (CCV) Description and OperationDescription Canister Close Valve (CCV) is installed on the canister ventilation line. It seals evaporative emission control system by shutting the canister from the atmosphere when leakage detecting system operates...
C..
Troubleshooting Ignition System SymptomSuspect AreaRemedyEngine will not start or is hard to start (Cranks OK)Ignition lock switchInspect ignition lock switch, or replace as requiredIgnition coilInspect ignition coil, or replace as requiredSpark plugsInspect spark plugs, or replace as requiredIgnition wiring disconnected or brokenRepair wiring, or replace as requiredRough idle or stallsIgnition wiringRepair wiring, or replace as requiredIgnition coilInspect ignition coil, or replace as requiredEngine hesitates/poor accelerationSpark plugs and spark plug cablesInspect spark plugs / cable, or replace as requiredIgnition wiringRepair wiring, or replace as requiredPoor mileageSpark plugs and spark plug cablesInspect spark plugs / cable, or replace as required Charging System SymptomSuspect AreaRemedyCharging warning indicator does not light with ignition switch "ON" and engine off...