Specification |
Item | Specification |
Ultrasonic sensor | Voltage rating | DC 12V |
Detecting range | 40 cm ~ 120 cm |
Operation voltage | DC 9 ~ 16V |
Operation current | MAX 300mA |
Operation temperature | -30°C ~ +80°C (-22°C ~ +176°C) |
Operation frequency | 48 ± 5KHz |
Number of sensors | 4EA (Left side, Left center, Right center, Right side) |
Hyundai Sonata LF 2014-2019 Service Manual: Evaporator Temperature Sensor Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the evaporator temperature sensor connector.
3.
Measure the resistance between terminal "+" and "-" of the evaporator temperature sensor.
Specification
Evaporator core temperature [°C (°F)]Resistance[K?]Voltage[V]-10 (14)8.123 ...
Hyundai Sonata LF 2014-2019 Service Manual: Water Temperature Control Assembly Components and Components Location
Components
1. Water temperature control assembly2. Water temperature sensor3. Gasket
...